During aerobic treatment, aeration supplies oxygen to the microorganisms that break down organic matter in industrial wastewater. The amount of oxygen they need varies with the volume and composition of the incoming wastewater. For plants planning an expansion or an upgrade, one question is especially important. Can the existing aeration system supply enough oxygen at peak demand?
To answer that question, consider how much oxygen the gas supply delivers and how much of it the aeration equipment transfers into the water.
Microorganisms use dissolved oxygen to break down organic matter. When more wastewater enters the tank, or when it contains more biodegradable organic matter, the microorganisms may consume more oxygen. If the aeration system cannot keep up, dissolved oxygen levels can fall.
Average daily wastewater volume tells only part of the story. At a factory that produces wastewater in batches, for example, the treatment load can rise sharply at certain times. Comparing incoming wastewater data with dissolved oxygen readings can show when the aeration system is under the most strain and how long those periods last.
In a bottom-diffused aeration system, pipes carry air or oxygen-rich gas to diffusers at the bottom of the tank. The diffusers release the gas as bubbles. As the bubbles rise, some of the oxygen dissolves in the water, where microorganisms can use it. Bubble size, water depth and diffuser condition all affect how much oxygen makes it into the water.
Gas flow and oxygen concentration determine how much oxygen enters the aeration system. The dissolved oxygen reading shows how much oxygen is in the water at a given time, as the system adds oxygen and the microorganisms consume it. Two tanks receiving the same oxygen flow can transfer different amounts of oxygen into the water if their diffusers or operating conditions differ.
If dissolved oxygen regularly drops during peak production, check whether the aeration equipment can supply more gas. If it is already close to maximum output, the plant may need additional oxygen supply during those hours. If low readings are limited to one area of the tank, check whether the diffusers in that area are working properly and receiving enough gas.
During quieter production periods, the tank may need less oxygen. If dissolved oxygen stays above the target range, the plant may be able to reduce gas flow while maintaining enough mixing in the tank.
If an existing air aeration system is near full capacity during peak production and dissolved oxygen still runs low, supplemental oxygen may help cover the shortfall. It may also be worth considering when an expansion will increase wastewater volumes and there is limited space for another aeration tank.
An on-site oxygen generator separates oxygen from ambient air at the plant. The system then delivers the oxygen to the aeration tank through suitable piping and aeration equipment. Plants can use on-site oxygen generation to supplement air aeration during peak periods or to provide a regular oxygen supply for an existing oxygen aeration process.
To determine the oxygen supply required for an aeration system, key parameters include wastewater flow rate, influent and target effluent BOD/COD levels, ammonia removal requirements, target dissolved oxygen level, and the aeration equipment’s oxygen transfer efficiency. Peak treatment loads and operating hours should also be considered.
Contact KSTK with these parameters to discuss a suitable oxygen supply solution for your wastewater treatment project.
Beyond conventional bottom-diffused aeration, micro- and nanobubble oxygenation offers another way to deliver oxygen into wastewater. In our next article, we’ll introduce KSTK’s microfine nano-bubble oxygenation system, explain how it works, and explore how it can be integrated with an on-site oxygen generator for wastewater treatment.